Clinical and radiographic results of locking plate with medial support screw in Proximal Humerus fracture - the more, the better?

近端肱骨骨折采用锁定钢板联合内侧支撑螺钉的临床和影像学结果——螺钉越多越好吗?

阅读:1

Abstract

BACKGROUND: The calcar of the proximal humerus is a fundamental structure for medial humeral column support. This study aimed to assess the outcome of osteosynthesis across cases of unstable proximal humerus fractures (PHFs) with medial calcar comminution, following treatment with a PHILOS locking plate and medial support screw (MSS). METHODS: Between January 2010 and December 2018, we retrospectively analyzed the outcomes of 121 cases of osteosynthesis for PHFs with medial column disruption. For the medial support, at least one oblique screw was inserted within 5 mm of the subchondral bone in the inferomedial quadrant of the humeral head. All patients were categorized into two groups: 26 patients in the single MSS group, and 95 in the multiple MSS group. Follow-up after at least an year involved clinical and radiographic outcome evaluations, and correspondingly measuring the Constant-Murley score, University of California, Los Angeles (UCLA) shoulder scale, pain visual analogue scale (VAS), major complications, neck-shaft angle (NSA), humeral head height (HHH), and the eventual time to bone union. Risk factors for the major complications were assessed by multivariate logistic regression analyses. RESULTS: The cohort's mean age was 64.4 ± 15.4 years, and the mean follow-up duration was 19.5 ± 7.6 months. At the final follow-up, between the single MSS and multiple MSS groups, no significant differences in the Constant-Murley score (p = 0.367), UCLA score (p = 0.558), VAS (p = 0.571), time to bone union (p = 0.621), NSA loss (p = 0.424), and HHH loss (p = 0.364) were observed. The incidence of complications (p = 0.446) based on the number of MSS were not significantly different. The initial insufficient reduction after surgery (of NSA < 125°) was found to be a significant risk factor for post-surgical complications. CONCLUSIONS: To treat unstable PHFs, the use of at least one MSS along with a locking plate system is sufficient to achieve satisfactory outcomes. Successful operative treatment using a locking plate for PHF treatment is inherent in anatomical fracture reduction, coupled with medial column support.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。