Risk factors of instrumentation failure after laminectomy and posterior cervical fusions (PCF)

椎板切除和后路颈椎融合术(PCF)后器械失效的风险因素

阅读:1

Abstract

BACKGROUND: For patients with multilevel degenerative cervical myelopathy, laminectomy and posterior cervical fusions (PCF) with instrumentation are widely accepted techniques for symptom relief. However, hardware failure is not rare and results in neck pain or even permanent neurological lesions. There are no in-depth studies of hardware-related complications following laminectomy and PCF with instrumentation. METHODS: The present study was a retrospective, single centre, observational study. Patients who underwent laminectomy and PCF with instrumentation in a single institution between January 2019 and January 2021 were included. Patients were divided into hardware failure and no hardware failure group according to whether there was a hardware failure. Data, including sex, age, screw density, end vertebra (C7 or T1), cervical sagittal alignment parameters (C2-C7 cervical lordosis, C2-C7 sagittal vertical axis, T1 slope, Cervical lordosis correction), regional Hounsfield units (HU) of the screw trajectory and osteoporosis status, were collected and compared between the two groups. RESULTS: We analysed the clinical data of 56 patients in total. The mean overall follow-up duration was 20.6 months (range, 12-30 months). Patients were divided into the hardware failure group (n = 14) and no hardware failure group (n = 42). There were no significant differences in the general information (age, sex, follow-up period) of patients between the two groups. The differences in fusion rate, fixation levels, and screw density between the two groups were not statistically significant (p > 0.05). The failure rate of fixation ending at T1 was lower than that at C7 (9% vs. 36.3%) (p = 0.019). The regional HU values of the pedicle screw (PS) and lateral mass screw (LMS) in the failure group were lower than those in the no failure group (PS: 267 ± 45 vs. 368 ± 43, p = 0.001; LMS: 308 ± 53 vs. 412 ± 41, p = 0.001). The sagittal alignment parameters did not show significant differences between the two groups before surgery or at the final follow-up (p > 0.05). The hardware failure rate in patients without osteoporosis was lower than that in patients with osteoporosis (14.3% vs. 57.1%) (p = 0.001). CONCLUSIONS: Osteoporosis, fixation ending at C7, and low regional HU value of the screw trajectory were the independent risk factors of hardware failure after laminectomy and PCF. Future studies should illuminate if preventive measures targeting these factors can help reduce hardware failure and identified more risk factors, and perform long-term follow-up.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。