Preliminary study of short-term outcomes and learning curves of robotic-assisted THA: comparison between closed platform robotic system and open platform robotic system

机器人辅助全髋关节置换术短期疗效及学习曲线的初步研究:封闭式平台机器人系统与开放式平台机器人系统的比较

阅读:1

Abstract

BACKGROUND: Both closed platform and open platform robotic-assisted total hip arthroplasty (THA) have recently been recommended as a viable treatment option for achieving accurate positioning of components. Yet, limited studies paid attention to the differences between the closed platform robotic system and the open platform robotic system. Hence, this study aimed to investigate clinical outcomes, radiographic outcomes, complication rates and learning curve of two systems. MATERIALS AND METHODS: We retrospectively included 62 patients (31 closed robotic system and 31 open robotic system) who underwent THA between February 2021 and January 2023. The demographics, operating time, cup positioning, complications and hip Harris score were evaluated. Learning curves of operation time was conducted using cumulative sum (CUSUM) analysis. RESULTS: There were no differences in surgical time (76.7 ± 12.1 min vs. 72.3 ± 14.8 min), estimated blood loss (223.2 ± 13.2 ml vs. 216.9 ± 17 ml) and Harris Hip score (HHS) between closed platform robotic system and the open platform robotic system. The closed robotic system and the open robotic system were associated with a learning curve of 9 cases and 7 cases for surgical time respectively, based on the satisfying rate of Lewinnek's safe zone outliers (1/31, 96.8%) and no occurrence of complication. Both robotic systems had significant reduction in overall surgical time, the duration of acetabulum registration, and estimated blood loss between learning phase and proficiency phase. CONCLUSION: The authors suggest that the surgical outcomes and safe zone outlier rate of the open robotic-assisted THA were similar to those of the closed robotic-assisted THA. These two robotic-assisted are associated with comparable learning curves and both have the precise positioning of acetabular component. From learning phase to proficiency phase, the rate of positions within the safe zone differed only marginally (88.9-100% vs. 85.7-100%) based on a rather low number of patients. This is not a statistically significant difference. Therefore, we suggest that THA undergoing with the robotic-assisted system is the relatively useful way to achieve planned acetabular cup position so far.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。