Reference intervals for common laboratory tests in Melanesian children

美拉尼西亚儿童常见实验室检查的参考区间

阅读:1

Abstract

Pediatric reference intervals for biochemical tests are often derived from studies in Western countries and may not be applicable to the developing world. No such intervals exist for Melanesian populations. The aim of this study was to provide specific reference intervals for children from Papua New Guinea (PNG). We assayed plasma from 327 healthy Melanesian children living in Madang Province for common biochemical and hematological analytes. We used well-validated commercially available assay methodology. Compared with reference intervals from children from Western countries and/or African children, there were substantial differences in hemoglobin, soluble transferrin receptor, ferritin, calcium, phosphate, and C-reactive protein. Differences in the upper limits of reference intervals for bilirubin and alanine aminotransferase were also observed. Available reference intervals from Western and African countries may be inappropriate in PNG and other Melanesian countries. This has implications for clinical care and safety monitoring in pharmaceutical intervention trials and vaccine studies.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。