Artemether-Lumefantrine Concentrations in Tablets and Powders from Ghana Measured by a New High-Performance Liquid Chromatography Method

采用新型高效液相色谱法测定加纳产片剂和粉剂中蒿甲醚-苯芴醇的浓度

阅读:1

Abstract

We developed and validated a new analytical method for the simultaneous quantification of artemether and lumefantrine in fixed-dose tablets and powders for reconstitution into pediatric suspensions (PSs). The method showed linearity (r(2) > 0.9947), precision (coefficient of variation < 2%), accuracy (deviation of mean from actual concentrations < 4%), and specificity (peak purities > 99%). The validated method was used to analyze 24 batches of fixed-dose tablets and PSs of artemether and lumefantrine. Of the samples, 23 were obtained using convenience sampling of commonly available brands within Accra in Ghana and one was obtained from Aarhus University Hospital. In all, 83.3% (confidence interval: 80-120%) passed for both artemether and lumefantrine contents, 16.7% failed by the U.S. Pharmacopoeia standards, 8.3% failed for one content, and 8.3% failed for both contents. All four products (16.7%) that failed were PSs, and two (8.3%) showed higher levels of artemether than prescribed (222% and 756%).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。