Deep learning estimation of effective atomic number for HU to RED calibration in dual energy photon counting CT

利用深度学习估计双能光子计数CT中HU到RED校准的有效原子序数

阅读:1

Abstract

This study introduces a deep learning (DL) approach to improve relative electron density (RED) estimation in dual-energy CT (DECT) through precise effective atomic number (EAN) prediction. A benchtop photon-counting detector CT acquired spectral images of a tissue-equivalent phantom, and a modified U-Net was trained on synthetic data to directly estimate EAN. Predicted EANs were converted to RED using a physics-based model. Performance was assessed on eight materials using mean absolute error (MAE), relative error, and residuals, with results compared to conventional Rutherford and stoichiometric methods. The DL model achieved an MAE of 0.08% for EAN, outperforming Rutherford (1.59%) and stoichiometric (1.54%) approaches. For RED estimation, DL reached a MAE of 0.62%, with residuals ranging from − 0.01 to 0.02 of theoretical values. Calibration analysis showed high linearity for conventional ΔHU-RED curves (R² ≈ 0.9995), but the DL-based method showed slightly higher linearity (R² = 0.9998). Overall, in this phantom study, the DL framework improved RED accuracy and HU–RED linearity compared with analytical methods. By providing a highly linear ΔHU–RED calibration curve in the phantom experiments conducted in this study, it enhances material differentiation and has the potential to support more precise dose calculations in future clinical applications.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。