Reducing the impact of geometric errors in flow computations using velocity measurements

利用速度测量降低几何误差对流量计算的影响

阅读:1

Abstract

Numerical blood flow simulations are typically set up from anatomical medical images and calibrated using velocity measurements. However, the accuracy of the computational geometry itself is limited by the resolution of the anatomical image. We first show that applying standard no-slip boundary conditions on inaccurately extracted boundaries can cause large errors in the results, in particular the pressure gradient. In this work, we therefore propose to augment the flow model calibration by slip/transpiration boundary conditions, whose parameters are then estimated using velocity measurements. Numerical experiments show that this methodology can considerably improve the accuracy of the estimated pressure gradients and 3D velocity fields when the vessel geometry is uncertain.