Pulsatile Vascular Afterload Measurement Improves Prediction of Right-Sided Heart Dysfunction in Undifferentiated and Left-Sided Pulmonary Hypertension

脉动血管后负荷测量可提高对未分化型和左侧肺动脉高压患者右心功能障碍的预测准确性

阅读:2

Abstract

BACKGROUND: The association between raised pulmonary artery pressures, pulmonary vascular resistance (PVR), and right-sided heart dysfunction is well recognized. The added value of pulsatile indices, specifically pulmonary arterial compliance (PAC) and characteristic impedance, remains unclear. This study aimed to identify the optimal vascular afterload model for predicting right-sided heart dysfunction in newly diagnosed pulmonary hypertension (PH). METHODS AND RESULTS: This was a prospective cohort study of 86 patients with suspected PH (60±16 years; 66 women) who underwent right-sided heart catheterization and cardiac magnetic resonance imaging. Right ventricular end-diastolic volume index (RVEDVi) and right atrial (RA) volume index were measured using cardiac magnetic resonance imaging. Vascular resistance, PAC, and characteristic impedance were measured using pulmonary artery pressure from right-sided heart catheterization and pulmonary artery flow from cardiac magnetic resonance imaging. Optimal model fit was determined by the lowest Akaike Information Criterion value. A total of 58% of patients had a right ventricular ejection fraction <50%, 63% had an increased RVEDVi, and 56% had an increased RA volume index. Overall, PVR was the best predictor of right ventricular ejection fraction <50% (P<0.01), increased RVEDVi (P<0.01), and RA volume index (P=0.02). However, for patients with a PVR <240 dynes.s.cm(-5), PAC(clinical) outperformed PVR in predicting right ventricular ejection fraction <50% (P=0.02) and increased RVEDVi (P=0.05). A 3-component model (PVR, PAC(clinical), and characteristic impedance) best predicted RA dilatation (P=0.05). In paired analysis, alternative methods of PAC quantification better predicted increased RVEDVi (PAC(decay) P=0.02) and RA volume index (PAC(area) P=0.02). PAC(clinical) <2.3 mL/mm Hg optimally predicted right-sided heart dysfunction (area under the curve, 0.768) and increased the AUC for PVR in undifferentiated/left-sided PH (0.89 versus 0.72). CONCLUSIONS: Pulsatile vascular afterload measurement improves right-sided heart dysfunction prediction in undifferentiated/left-sided PH. More accurate PAC measurement methods could further enhance prognostic accuracy, while a PVR ≥240 dynes.s.cm(-5) remains a valuable threshold for precapillary PH.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。