Robust thoracic CT image registration with environmental adaptability using dynamic Welsch's function and hierarchical structure-awareness strategy

基于动态Welsch函数和分层结构感知策略的鲁棒性胸部CT图像配准及其环境适应性

阅读:1

Abstract

BACKGROUND: Robust registration of thoracic computed tomography (CT) images is strongly impacted by motion during acquisition, high-density objects, and noise, particularly in lower-dose acquisitions. Despite the enhanced registration speed achieved by popular deep learning (DL) methods, their robustness is often neglected. This study aimed to develop a robust thoracic CT image registration algorithm to address the aforementioned issues. METHODS: A novel, anatomical structure-aware hierarchical registration. By this method, employing a divide-and-conquer approach, dissimilarity metrics, and regularization terms are selected for different regions based on their distinct image features and motion patterns. These terms are then innovatively reconstructed using the Welsch's function, which allows control over the penalty distribution on the loss values. Subsequently, a novel Welsch parameter update strategy is designed for the task of thoracic CT image registration, enabling dynamic sparsity in registration from coarse to fine levels to accommodate various levels of noise and sliding motion. Moreover, the majorization-minimization (MM) algorithm is used to handle the Welsch terms by constructing surrogate functions based on the current variable values for variable update, thereby reducing the complexity of optimization. RESULTS: Experimental results on publicly available deformable image registration lab four-dimensional CT (DIR-Lab 4DCT) and chronic obstructive pulmonary disease (COPD) datasets with and without noise, showed that our proposed method achieves comparable performance to state-of-the-art methods in noise-free scenarios [1.14 and 1.19 mm compared to 1.14 and 1.35 mm target registration errors (TREs)], while demonstrating superior robustness in the presence of noise (1.78 and 2.38 mm compared to 2.00 and 3.31 mm TREs). Ablation studies also validated the effectiveness of each component in the method. CONCLUSIONS: A novel and robust algorithm for thoracic CT image registration has been proposed, which has significant potential for valuable clinical applications, including surgical quantitative imaging.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。