Sink Drains in a Neonatal Intensive Care Unit: A Retrospective Risk Assessment and Evaluation

新生儿重症监护室水槽排水管:回顾性风险评估与评价

阅读:1

Abstract

Water systems in health care facilities can form reservoirs for Gram-negative bacteria. While planning a new neonatal intensive care unit (NICU), we performed a retrospective evaluation of potential risks from water-diverting systems on the existing NICU of our tertiary care University Hospital. During 2017 to 2023, we recorded nine nosocomial cluster events with bacterial pathogens in our NICU. Of these, three clusters of Gram-negative bacteria were potentially related to sink drains: A Klebsiella oxytoca, a Pseudomonas aeruginosa, and an Enterobacter hormaechei cluster were uncovered by clinical routine screening of patients and breastmilk samples. They were confirmed using whole-genome sequencing and a subsequent core genome multilocus sequence typing (cgMLST) algorithm. Our observations highlight that the implementation of sink drains in a NICU may have negative effects on patients' safety. Construction planning should concentrate on the avoidance of washbasins in patient rooms when redesigning sensitive areas such as NICUs.