New Frontiers in Autoimmune Diagnostics: A Systematic Review on Saliva Testing

自身免疫诊断的新前沿:唾液检测的系统评价

阅读:1

Abstract

(1) Background: Immunological laboratory testing is known to be complex, and it is usually performed in tertiary referral centers. Many criticalities affect diagnostic immunological testing, such as limited availability, the need for specifically trained laboratory staff, and potential difficulties in collecting blood samples, especially in the most vulnerable patients, i.e., the elderly and children. For this reason, the identification of a new feasible and reliable methodology for autoantibody detection is urgently needed. (2) Methods: We designed a systematic review to investigate the available literature on the utilization of saliva samples for immunological testing. (3) Results: A total of 170 articles were identified. Eighteen studies met the inclusion criteria, accounting for 1059 patients and 671 controls. The saliva collection method was mostly represented by passive drooling (11/18, 61%), and the most frequently described methodology for antibody detection was ELISA (12/18, 67%). The analysis included 392 patients with rheumatoid arthritis, 161 with systemic lupus erythematosus, 131 with type 1 diabetes mellitus, 116 with primary biliary cholangitis, 100 with pemphigus vulgaris, 50 with bullous pemphigoids, 49 with Sjogren syndrome, 39 with celiac disease, 10 with primary antiphospholipid syndromes, 8 with undifferentiated connective tissue disease, 2 with systemic sclerosis, and 1 with autoimmune thyroiditis. The majority of the reviewed studies involved adequate controls, and saliva testing allowed for a clear distinction of patients (10/12 studies, 83%). More than half of the papers showed a correlation between saliva and serum results (10/18, 55%) for autoantibody detection, with varying rates of correlation, sensitivity, and specificity. Interestingly, many papers showed a correlation between saliva antibody results and clinical manifestations. (4) Conclusions: Saliva testing might represent an appealing alternative to serum-based testing for autoantibody detection, considering the correspondence with serum testing results and the correlation with clinical manifestations. Nonetheless, standardization of sample collection processing, maintenance, and detection methodology has yet to be fully addressed.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。