Calibration trial of an innovative medical device (NEVVA(©) ) for the evaluation of pain in non-communicating patients in the intensive care unit

一项针对重症监护病房中无法沟通的患者疼痛评估的创新型医疗设备(NEVVA(©))的校准试验

阅读:1

Abstract

BACKGROUND: Pain management is an essential and complex issue for non-communicative patients undergoing sedation in the intensive care unit (ICU). The Behavioral Pain Scale (BPS), although not perfect for assessing behavioral pain, is the gold standard based partly on clinical facial expression. NEVVA(©) , an automatic pain assessment tool based on facial expressions in critically ill patients, is a much-needed innovative medical device. METHODS: In this prospective pilot study, we recorded the facial expressions of critically ill patients in the medical ICU of Caen University Hospital using the iPhone and Smart Motion Tracking System (SMTS) software with the Facial Action Coding System (FACS) to measure human facial expressions metrically during sedation weaning. Analyses were recorded continuously, and BPS scores were collected hourly over two 8 h periods per day for 3 consecutive days. For this first stage, calibration of the innovative NEVVA(©) medical device algorithm was obtained by comparison with the reference pain scale (BPS). RESULTS: Thirty participants were enrolled between March and July 2022. To assess the acute severity of illness, the Sequential Organ Failure Assessment (SOFA) and the Simplified Acute Physiology Score (SAPS II) were recorded on ICU admission and were 9 and 47, respectively. All participants had deep sedation, assessed by a Richmond Agitation and Sedation scale (RASS) score of less than or equal to -4 at the time of inclusion. One thousand and six BPS recordings were obtained, and 130 recordings were retained for final calibration: 108 BPS recordings corresponding to the absence of pain and 22 BPS recordings corresponding to the presence of pain. Due to the small size of the dataset, a leave-one-subject-out cross-validation (LOSO-CV) strategy was performed, and the training results obtained the receiver operating characteristic (ROC) curve with an area under the curve (AUC) of 0.792. This model has a sensitivity of 81.8% and a specificity of 72.2%. CONCLUSION: This pilot study calibrated the NEVVA(©) medical device and showed the feasibility of continuous facial expression analysis for pain monitoring in ICU patients. The next step will be to correlate this device with the BPS scale.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。