Utility of spectral CT with orthopedic metal artifact reduction algorithms for (125)I seeds implantation in mediastinal and hepatic tumors

光谱CT结合骨科金属伪影减少算法在(125)I粒子植入纵隔和肝脏肿瘤中的应用

阅读:1

Abstract

BACKGROUND: Virtual monochromatic image (VMI) combined with orthopedic metal artifact reduction algorithms (VMI + O-MAR) can effectively reduce artifacts caused by metal implants of different types. Nevertheless, so far, no study has systematically evaluated the efficacy of VMI + O-MAR in reducing various types of metal artifacts induced by (125)I seeds. The aim of this study was to assess the effectiveness of combining spectral computed tomography (CT) images with O-MAR in reducing metal artifacts and improving the image quality affected by artifacts in patients after (125)I radioactive seeds implantation (RSI). METHODS: A total of 45 patients who underwent dual-layer detector spectral CT (DLCT; IQon, Philips Healthcare) scanning of mediastinal and hepatic tumors after (125)I RSI were retrospectively included. Spectral data were reconstructed into conventional image (CI), VMI, CI combined with O-MAR (CI + O-MAR), and VMI + O-MAR to evaluate the de-artifact effect and image quality improvement. Objective indicators included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and artifact index (AI) of lesions affected by artifacts. Subjective indicators included assessment of overcorrected artifacts and new artifacts, different morphology of artifacts, and overall image quality. RESULTS: In artifact-affected lesion areas, SNR and CNR in the CI/VMI + O-MAR groups were better than those in CI groups (all P values <0.05). The AI showed a downward trend as VMI keV increased (all P values <0.001). The AI values of the CI/VMI (50-150 keV) group were all higher than the groups of CI/VMI + O-MAR (50-150 keV) (P<0.001). Overcorrection artifacts and new artifacts were concentrated in the VMI50/70 keV groups. In the evaluation of artifact morphology, as the VMI keV increased, the number of near-field banding artifacts in hyperdense artifacts gradually decreased, whereas the number of minimal or no artifacts increased, and the total number of hyperdense artifacts were decreased. The diagnostic and image quality scores of hyperdense artifacts were higher than those of hypodense artifacts as VMI keV increased. CONCLUSIONS: High VMI level combined with O-MAR substantially improve objective and subjective image quality, lesion display ability, and diagnostic confidence of CT follow-up after (125)I RSI, especially at the VMI + O-MAR 150 keV level.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。