Evaluation of the Feasibility of 2D-SWE to Measure Liver Stiffness in Healthy Dogs and Analysis of Possible Confounding Factors

评估二维剪切波弹性成像技术测量健康犬肝脏硬度的可行性及可能混杂因素分析

阅读:1

Abstract

(1) Background: Two-dimensional shear wave elastography (2D-SWE) is a non-invasive method widely used in human medicine to assess the extent of liver fibrosis but only rarely applied to veterinary medicine. This study aimed to measure liver stiffness in healthy dogs and investigate the factors that impacted 2D-SWE measurement. (2) Methods: In total, 55 healthy dogs were enrolled and subjected to 2D-SWE measurements before and after anesthesia administration. Post-anesthesia 2D-SWE measurements and computerized tomography (CT) scans were obtained. (3) Results: The liver stiffness range in healthy dogs was 3.96 ± 0.53 kPa. In a stratified analysis based on confounding factors, liver stiffness was influenced by measurement site and anesthesia, but not by sex. No correlation was observed between liver stiffness and weight or liver CT attenuation. (4) Conclusions: 2D-SWE is feasible for liver stiffness measurement in dogs. Anesthesia and measurement site are sources of variability. Therefore, these factors should be considered while recording 2D-SWE measurements. Our data on liver stiffness in healthy dogs can serve as the basis for future studies on 2D-SWE to assess pathological conditions in dogs.