Elliptical and spherical heads show similar obligate glenohumeral translation during axial rotation in total shoulder arthroplasty

在全肩关节置换术中,椭圆形和球形假体头在轴向旋转过程中均表现出相似的肩肱关节平移。

阅读:1

Abstract

BACKGROUND: Elliptical shape humeral head prostheses have been recently proposed to reflect a more anatomic shoulder replacement. However, its effect on obligate glenohumeral translation during axial rotation compared to a standard spherical head is still not well understood. The purpose of the study was to compare obligate humeral translation during axial rotation using spherical and elliptical shaped humeral head prostheses. It was hypothesized that the spherical head design would show significantly more obligate translation when compared to the elliptical design. METHODS: Six fresh-frozen cadaveric shoulders were utilized for biomechanical testing of internal (IR) and external (ER) rotation at various levels of abduction (0°, 30°, 45°, 60°) with lines of pull along each of the rotator cuff muscles. Each specimen underwent the following three conditions: (1) native; total shoulder arthroplasty (TSA) using (2) an elliptical and (3) spherical humeral head implant. Obligate translation during IR and ER was quantified using a 3-dimensional digitizer. The radius of curvature of the superoinferior and anteroposterior dimensions of the implants was calculated across each condition. RESULTS: Posterior and inferior translation as well as compound motion of spherical and elliptical heads during ER was similar at all abduction angles (P > 0.05, respectively). Compared to the native humeral head, both implants demonstrated significantly decreased posterior translation at 45° (elliptical: P = 0.003; spherical: P = 0.004) and 60° of abduction (elliptical: P < 0.001; spherical: P < 0.001). During internal rotation at 0° abduction, the spherical head showed significantly more compound motion (P = 0.042) compared to the elliptical head. The spherical implant also demonstrated increased anterior translation and compound motion during internal rotation at 60° abduction (P < 0.001) compared to the resting state. This difference was not significant for the native or elliptical head design at this angle (P > 0.05). CONCLUSION: In the setting of TSA, elliptical and spherical head implants showed similar obligate translation and overall compound motion during axial rotation. A gained understanding of the consequences of implant head shape in TSA may guide future surgical implant choice for better recreation of native shoulder kinematics and potentially improved patient outcomes. LEVEL OF EVIDENCE: Controlled Laboratory Study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。