Psychometric properties of a standardized protocol of muscle strength assessment by hand-held dynamometry in healthy adults: a reliability study

健康成年人手持式测力计肌肉力量评估标准化方案的心理测量学特性:一项信度研究

阅读:2

Abstract

BACKGROUND: Maximal isometric muscle strength (MIMS) assessment is a key component of physiotherapists' work. Hand-held dynamometry (HHD) is a simple and quick method to obtain quantified MIMS values that have been shown to be valid, reliable, and more responsive than manual muscle testing. However, the lack of MIMS reference values for several muscle groups in healthy adults with well-known psychometric properties limits the use and the interpretation of these measures obtained with HHD in clinic. OBJECTIVE: To determine the intra- and inter-rater reliability, standard error of measurement (SEM) and minimal detectable change (MDC) of MIMS torque values obtained with HHD. METHODS: Intra and Inter-rater Reliability Study. The MIMS torque of 17 muscle groups was assessed by two independent raters at three different times in 30 healthy adults using a standardized HHD protocol using the MEDup™ (Atlas Medic, Québec, Canada). Participants were excluded if they presented any of the following criteria: 1) participation in sport at a competitive level; 2) degenerative or neuromusculoskeletal disease that could affect torque measurements; 3) traumatic experience or disease in the previous years that could affect their muscle function; and 4) use of medication that could impact muscle strength (e.g., muscle relaxants, analgesics, opioids) at the time of the evaluation. Intra- and inter-rater reliability were determined using two-way mixed (intra) and random effects (inter) absolute agreement intraclass correlation coefficients (ICC: 95% confidence interval) models. SEM and MDC were calculated from these data. RESULTS: Intra- and inter-rater reliability were excellent with ICC (95% confidence interval) varying from 0.90 to 0.99 (0.85-0.99) and 0.89 to 0.99 (0.55-0.995), respectively. Absolute SEM and MDC for intra-rater reliability ranged from 0.14 to 3.20 Nm and 0.38 to 8.87 Nm, respectively, and from 0.17 to 5.80 Nm and 0.47 to 16.06 Nm for inter-rater reliability, respectively. CONCLUSIONS: The excellent reliability obtained in this study suggest that the use of such a standardized HHD protocol is a method of choice for MIMS torque measurements in both clinical and research settings. And the identification of the now known metrological qualities of such a protocol should encourage and promote the optimal use of manual dynamometry.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。