Treatment outcomes of applying external fixator on distal radius fractures: a randomized clinical trial to compare between two directions of force exertion in parallel to radius shaft and perpendicular to the distal radius articular surface

外固定器治疗桡骨远端骨折的疗效:一项随机临床试验,比较平行于桡骨干和垂直于桡骨远端关节面的两种施力方向。

阅读:2

Abstract

BACKGROUND: External fixation has been one of the conventional managements of unstable distal radius fracture. The main aim of this paper is to compare two methods of applying distractive force along the radius shaft versus perpendicular to the distal radius articular surface. DESIGN: Sixty patients with unstable distal radius fracture were included in present clinical trial and randomized in two groups, using block randomization method. In group A (first arm), distraction force was exerted parallel to the radius shaft. In group B (second arm), the external fixator was adjusted based on radial and palmar tilt of the mean population healthy wrist so that distraction was exerted perpendicular to the wrist articular surface. METHODS: Radiological and clinical parameters were evaluated in both groups of patients pre-operatively, immediately after surgery, and 6 weeks post-operatively. We also followed up patients clinically at 12 weeks after surgery. Patient-Rated Wrist Evaluation (PRWE), Mayo wrist score, and Quick Disabilities of the Arm, Shoulder and Hand (DASH) questionnaires were used in order to assess patients' clinical and functional states. RESULTS: The method used in group B resulted in better improvement of palmar tilt both immediately (P = 0.007) and at 6 weeks follow up (P = 0.013) post-operatively in comparison with patients in group A. Radius height and radial inclination were also better restored when using the proposed modified method (P = 0.001 and < 0.001, respectively). There was no difference in any of clinical results (range of motion, grip strength, PRWE, Mayo, and DASH scores) between two groups of study, 12 weeks after surgery. CONCLUSION: Applying distractive force perpendicular to the distal radius articular surface seems to improve some radiological outcomes, probably due to better reduction maintenance, when compared with the technique of applying distraction force along distal radius shaft axis. LEVEL OF EVIDENCE: Level I (clinical trial study). TRIAL REGISTRATION: This study is registered at Iranian Registry of Clinical Trials (IRCT) with approval code of IRCT20200313046759N1.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。