Effect of loading history on material properties of human heel pad: an in-vivo pilot investigation during gait

负荷历史对人体足跟垫材料特性的影响:步态过程中的体内初步研究

阅读:1

Abstract

BACKGROUND: This study was aimed to develop a novel dynamic measurement technique for testing the material properties and investigating the effect of continuous compression load on the structural and mechanical properties of human heel pad during actual gait. METHODS: The dual fluoroscopic imaging system (DFIS) and dynamic foot-ground contact pressure-test plate were used for measuring the material properties, including primary thickness, peak strain, peak stress, elastic modulus, viscous modulus and energy dissipation rate (EDR), both at time zero and following continuous loading. Ten healthy pilot subjects, aged from 23 to 72 (average: 46.5 ± 17.6), were enrolled. A "three-step gait cycle" is performed for all subjects, with the second step striking at a marked position on the force plate with the heel to maintain the location of the tested foot to be in the view of fluoroscopes. The subjects were measured at both relaxed (time-zero group) and fatigue (continuous-loading group) statuses, and the left and right heels were measured using the identical procedures. RESULTS: The peak strain, peak stress, elastic modulus, and EDR are similar before and after continuous load, while the viscous modulus was significantly decreased (median: 43.9 vs. 20.37 kPa•s; p < 0.001) as well as primary thicknesses (median: 15.99 vs. 15.72 mm; p < 0.001). Age is demonstrated to be moderately correlated with the primary thicknesses both at time zero (R = -0.507) and following continuous load (R = -0.607). The peak stress was significantly correlated with the elastic modulus before (R = 0.741) and after continuous load (R = 0.802). The peak strain was correlated with the elastic modulus before (R = -0.765) and after continuous load (R = -0.801). The correlations between the viscous modulus and peak stress/ peak strain are similar to above(R = 0.643, 0.577, - 0.586 and - 0.717 respectively). The viscous modulus is positively correlated with the elastic modulus before (R = 0.821) and after continuous load (R = 0.784). CONCLUSIONS: By using dynamic fluoroscopy combined with the plantar pressure plate, the in vivo viscoelastic properties and other data of the heel pad in the actual gait can be obtained. Age was negatively correlated with the primary thickness of heel pad and peak strain, and was positively correlated with viscous modulus. Repetitive loading could decrease the primary thickness of heel pad and viscous modulus.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。