Functional outcomes before and after implant removal in patients with posttraumatic shoulder stiffness and healed proximal humerus fractures: does implant material (PEEK vs. titanium) have an impact? - a pilot study

创伤后肩关节僵硬伴肱骨近端骨折愈合患者植入物取出前后的功能结果:植入物材料(PEEK 与钛)是否会产生影响?——一项初步研究

阅读:1

Abstract

BACKGROUND: Posttraumatic shoulder stiffness remains a problem after proximal humerus fracture (PHF) despite good healing rates. The aim of this pilot study was to determine whether the implant material and overlying soft tissue have an effect on shoulder range of motion (ROM) before and after implant removal (IR). METHODS: 16 patients (mean age 55.2 ± 15.3 (SD) years; 62.5% female) were included who underwent operative treatment with locking plates of either carbon fiber reinforced Polyetheretherketone (PEEK) (PEEKPower® humeral fracture plate, Arthrex, Naples, Florida, USA, n = 8) or titanium alloy (Ti) (Philos®, DePuy Synthes, Johnson & Johnson Medical, Raynham, Massachusetts, USA, n = 8) for PHF. All patients presented with a limited ROM and persistent pain in everyday life after the fracture had healed, whereupon IR was indicated. ROM before and after IR were compared as well as the Constant Score (CS) and the CS compared to the contralateral shoulder (%CS) 1 year after IR. RESULTS: In group PEEK, elevation was 116.3° ± 19.2° pre- and 129.4° ± 23.7° post-IR (p = 0.027). External rotation was 35.0° ± 7.6° pre- and 50.6° ± 21.8° post-IR (p = 0.041). External rotation with the humerus abducted 90° was 38.8° ± 18.1° pre- and 52.5° ± 25.5° post-IR (p = 0.024). In group Ti, elevation was 110.0° ± 34.6° pre- and 133.8° ± 31.1° post-IR (p = 0.011). External rotation with the humerus at rest was 33.8° ± 23.1° pre- and 48.8° ± 18.7° post-IR (p = 0.048). External rotation with the humerus abducted 90° was 40.0° ± 31.6° pre- and 52.5° ± 22.5° post-IR (p = 0.011). Comparison of the two implant materials showed no significant difference. The overall CS was 90.3 ± 8.8, the %CS was 91.8% ± 14.7%. CONCLUSION: There was no significant difference in ROM, CS and %CS with respect to plate materials, although lower cell adhesion is reported for the hydrophobic PEEK. However, all patients showed improved functional outcomes after IR in this pilot study. In patients with shoulder stiffness following locked plating for PHF, implants should be removed and open arthrolysis should be performed, independently from the hardware material. LEVEL OF EVIDENCE: II.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。