Analysis of measurement changes in pelvic incidence according to pelvic rotation using a three-dimensional model

利用三维模型分析骨盆旋转引起的骨盆入射角测量变化

阅读:1

Abstract

BACKGROUND: Pelvic incidence (PI) is used as a key parameter in surgical correction of adult spinal deformity (ASD). However, reflecting the exact center or inclination of the three-dimensional anatomical structures on the two-dimensional (2D) sagittal radiographs is limited, resulting in measurement errors. Therefore, we evaluated whether there is a change in PI measurement according to the actual rotation of the pelvis, and conducted a study on a more accurate method for PI measurement using 2D sagittal radiographs. METHODS: From 2014 to 2015, the data of 30 patients who visited our outpatient clinic were analyzed retrospectively. CT scans including those of the lower lumbar spine, pelvis, and both femurs in the DICOM format were imported to Mimics Research 17.0 (Materialise NV, Belgium), SolidWorks (Dassault systems, France), and AutoCAD 2014 (AUTODESK, US). The changes in PI according to vertical and horizontal pelvic rotations were evaluated. RESULTS: The average PIs according to the horizontal pelvic rotations measured on AutoCAD with 0°, 5°, 10°, 15°, 20°, 25°, 30°, 35°, and 40° were 48.8°, 48.7°, 48.3°, 47.8°, 46.9°, 45.6°, 44.0°, 42.2°, and 39.9°, respectively. The PI with an acceptable error of 6° on radiographs was 35° in the horizontal pelvic rotation. The average PIs according to the vertical pelvic rotations measured on AutoCAD with 0°, 5°, 10°, 15°, 20°, 25°, 30°, 35°, and 40° were 48.8°, 49.0°, 49.5°, 50.2°, 51.3°, 52.7°, 54.4°, 56.6°, and 59.4°, respectively. The PI with an acceptable error of 6° on radiographs was 30° in the vertical pelvic rotation. CONCLUSIONS: This study revealed that the PI value could differ from the actual anatomical value due to the horizontal and vertical rotation of the pelvis while acquiring the radiograph. Regarding whole-spine lateral radiographs, errors in PI measurement may occur due to pelvic rotation or nonvertical projection of X-rays. In the standing pelvic lateral radiographs, ensuring superposition of the femoral heads at the center and obtaining the straight sacral endplate by referring to CT or magnetic resonance imaging would be a more accurate measurement method to define PI.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。