Validity of classification of distal radial fractures in the Swedish fracture register

瑞典骨折登记册中桡骨远端骨折分类的有效性

阅读:1

Abstract

BACKGROUND: Distal radial fractures (DRF) are one of the most common fractures with a small peak in incidence among young males and an increasing incidence with age among women. The reliable classification of fractures is important, as classification provides a framework for communicating effectively on clinical cases. Fracture classification is also a prerequisite for data collection in national quality registers and for clinical research. Since its inception in 2011, the Swedish Fracture Register (SFR) has collected data on more than 490,000 fractures. The attending physician classifies the fracture according to the AO/OTA classification upon registration in the SFR. Previous studies regarding the classification of distal radial fractures (DRF) have shown difficulties in inter- and intra-observer agreement. This study aims to assess the accuracy of the registration of DRF in adults in the SFR as it is carried out in clinical practice. METHODS: A reference group of three experienced orthopaedic trauma surgeons classified 128 DRFs, randomly retrieved from the SFR, at two classification sessions 6 weeks apart. The classification the reference group agreed on was regarded as the gold standard classification for each fracture. The accuracy of the classification in the SFR was defined as the agreement between the gold standard classification and the classification in the SFR. Inter- and intra-observer agreement was evaluated and the degree of agreement was calculated as Cohen's kappa. RESULTS: The accuracy of the classification of DRF in the SFR was kappa = 0.41 (0.31-0.51) for the AO/OTA subgroup/group and kappa = 0.48 (0.36-0.61) for the AO/OTA type. This corresponds to moderate agreement. Inter-observer agreement ranged from kappa 0.22-0.48 for the AO/OTA subgroup/group and kappa 0.48-0.76 for the AO/OTA type. Intra-observer agreement ranged from kappa 0.52-0.70 for the AO/OTA subgroup/group and kappa 0.71-0.76 for the AO/OTA type. CONCLUSIONS: The study shows moderate accuracy in the classification of DRF in the SFR. Although the degree of accuracy for DRF appears to be lower than for other fracture locations, the accuracy shown in the current study is similar to that in previous studies of DRF.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。