The accelerometer-based navigation system demonstrated superior radiological outcomes in restoring mechanical alignment and component sagittal positioning in total knee arthroplasty

基于加速度计的导航系统在全膝关节置换术中恢复机械对线和组件矢状位定位方面表现出优异的放射学效果。

阅读:1

Abstract

BACKGROUND: This study aimed to determine whether the accelerometer-based navigation (ABN) could improve the accuracy of restoring mechanical axis (MA), component positioning, and clinical outcomes compared to conventional (CON) total knee arthroplasty (TKA). METHODS: A total of 301 consecutive patients (ABN: 27, CON: 274) were included. A 1:4 propensity score matching (PSM) was performed between the two groups according to preoperative demographic and clinical parameters. The postoperative MA, femoral coronal angle (FCA), femoral sagittal angle (FSA), tibial coronal angle (TCA) and tibial sagittal angle (TSA) were compared. Absolute deviations of aforementioned angles were calculated as the absolute value of difference between the exact and ideal value and defined as norms if within 3°, otherwise regarded as outliers. Additional clinical parameters, including the Knee Society knee and function scores (KSKS and KSFS) and range of motion (ROM), were assessed at final follow-up (FU) (mean FU was 21.88 and 21.56 months respectively for ABN and CON group). A secondary subgroup analysis and comparison on clinical outcomes were conducted between norms and outliers in different radiological parameters. RESULTS: A total of 98 patients/102 knees were analyzed after the PSM (ABN: 21 patients/24 knees, CON: 77 patients/78 knees). In the ABN group, the mean MA, FCA and TSA were significantly improved (p = 0.019, 0.006, < 0.001, respectively). Proportions of TKAs within a ± 3°deviation were significantly improved in all the postoperative radiological variables except for TCA (p = 0.003, 0.021, 0.042, 0.013, respectively for MA, FCA, FSA, and TSA). The absolute deviations of FSA and TSA were also significantly lower in the ABN group (p = 0.020, 0.048, respectively). No significant differences were found in either mean value, absolute deviation or outlier ratio of TCA between two groups. On clinical outcomes, there were no significant differences between two groups, although KSKS, KSFS and ROM (p < 0.01, respectively) dramatically improved compared to baseline. The subgroup analysis also demonstrated no statistical difference on clinical outcomes between the outliers and norms in varied radiological parameters. CONCLUSIONS: The ABN could improve the accuracy and precision of mechanical alignment and component positioning without significant improvement of clinical outcomes. Further high quality studies with long term FU are warranted to comprehensively evaluate the value of the ABN.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。