Reliability of tibiofemoral contact area and centroid location in upright, open MRI

直立开放式磁共振成像中胫股接触面积和质心位置的可靠性

阅读:1

Abstract

BACKGROUND: Imaging cannot be performed during natural weightbearing in biomechanical studies using conventional closed-bore MRI, which has necessitated simulating weightbearing load on the joint. Upright, open MRI (UO-MRI) allows for joint imaging during natural weightbearing and may have the potential to better characterize the biomechanical effect of tibiofemoral pathology involving soft tissues. However open MRI scanners have lower field strengths than closed-bore scanners, which limits the image quality that can be obtained. Thus, there is a need to establish the reliability of measurements in upright weightbearing postures obtained using UO-MRI. METHODS: Knees of five participants with prior anterior cruciate ligament (ACL) rupture were scanned standing in a 0.5 T upright open MRI scanner using a 3D DESS sequence. Manual segmentation of cartilage regions in contact was performed and centroids of these contact areas were automatically determined for the medial and lateral tibiofemoral compartments. Inter-rater, test-retest, and intra-rater reliability were determined and quantified using intra-class correlation (ICC(3,1)), standard error of measurement (SEM), and smallest detectable change with 95% confidence (SDC(95)). Accuracy was assessed by using a high-resolution 7 T MRI as a reference. RESULTS: Contact area and centroid location reliability (inter-rater, test-retest, and intra-rater) for sagittal scans in the medial compartment had ICC(3,1) values from 0.95-0.99 and 0.98-0.99 respectively. In the lateral compartment, contact area and centroid location reliability ICC(3,1) values ranged from 0.83-0.91 and 0.95-1.00 respectively. The smallest detectable change in contact area was 1.28% in the medial compartment and 0.95% in the lateral compartment. Contact area and centroid location reliability for coronal scans in the medial compartment had ICC(3,1) values from 0.90-0.98 and 0.98-1.00 respectively, and in the lateral compartment ICC(3,1) ranged from 0.76-0.94 and 0.93-1.00 respectively. The smallest detectable change in contact area was 0.65% in the medial compartment and 1.41% in the lateral compartment. Contact area was accurate to within a mean absolute error of 11.0 mm(2). CONCLUSIONS: Knee contact area and contact centroid location can be assessed in upright weightbearing MRI with good to excellent reliability. The lower field strength used in upright, weightbearing MRI does not compromise the reliability of tibiofemoral contact area and centroid location measures.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。