Binary Tönnis classification: simplified modification demonstrates better inter- and intra-observer reliability as well as agreement in surgical management of hip pathology

二元Tönnis分类:简化的改良版在髋关节病变的手术治疗中表现出更好的观察者间和观察者内信度以及一致性。

阅读:1

Abstract

BACKGROUND: The traditional Tönnis Classification System has inherent drawbacks as it is vulnerable to the subjectivity of a four-grade system. A two-grade classification could potentially be more reliable. The purpose of this study is to (1) compare the inter-observer and intra-observer reliability of the traditional Tönnis Classification System and a simplified Binary Tönnis Classification System for hip osteoarthritis and to (2) evaluate the clinical applicability of both systems. Our hypothesis is that the proposed Binary Tönnis Classification System will have better reliability and agreement for surgical decision-making. METHODS: Forty consecutive patients were selected to participate in this study. Patients were included in this study if they were between 35 and 60 years old. Patients were excluded if they had prior hip surgeries or conditions. All radiographs were randomized and blinded by a non-observer. Five fellowship-trained hip surgeons from a single center, in a fully crossed design, analyzed and graded all the radiographs utilizing the traditional Tönnis Classification System and the proposed Binary Tönnis Classification System. Intra- and inter-observer reliability values for both the systems were calculated using the Cohen's κ coefficient. A multi-rater κ was calculated using the weighted Fleiss method. RESULTS: The study sample contained 40 anterosuperior hip radiographs. For the traditional Tönnis Classification System, the weighted κ showed a fair inter-observer reliability (κ = 0.474) and excellent intra-observer reliability (κ mean = 0.866). For the proposed Binary Tönnis Classification System, both inter-observer and intra-observer reliability demonstrated excellent values, (κ = 0.858 and 0.928, respectively). On average, the Binary Tönnis Classification System correctly captured 87% of cases. When the traditional Tönnis Classification System was dichotomized, the capture rate was 84%. CONCLUSION: A simplified binary Tönnis Classification System demonstrates better reliability and clinical implementation than the traditional Tönnis Classification System.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。