The evaluation of the distance between the popliteus tendon and the lateral collateral ligament footprint and the implant in Total knee Arthroplasty using a 3-dimensional template

使用三维模板评估全膝关节置换术中腘肌腱与外侧副韧带止点及假体之间的距离

阅读:1

Abstract

BACKGROUND: The popliteus tendon (PT) or lateral collateral ligament (LCL) stabilizes the postero-lateral aspects of the knees. When surgeons perform total knee arthroplasty (TKA), PT and LCL iatrogenic injuries are a risk because the femoral attachments are relatively close to the femoral bone resection area. The purpose of this study was to evaluate the distance between the PT or LCL footprint and the TKA implant using a 3D template system and to evaluate any significant differences according to the implant model. METHODS: Eighteen non-paired formalin fixed cadaveric lower limbs were used (average age: 80.3). Whole length lower limbs were resected from the pelvis. All the surrounding soft tissue except the PT, knee ligaments and meniscus were removed from the limb. Careful dissection of the PT and LCL was performed, and the femoral footprints were detected. Each footprint periphery was marked with a 1.5 mm K-wire. Computed tomography (CT) scanning of the whole lower limb was then performed. The CT data was analyzed with a 3D template system. This simulation models for TKA were the Journey II BCS and the Persona PS. The area of each footprint, and the length between the most distal and posterior point of the lateral femoral condyle and the edge of each footprint were measured. Matching the implant model to the CT image of the femur, the shortest length between each footprint and the bone resection area were calculated. RESULTS: PT and LCL footprint were detected in all knees. The area of the PT and LCL footprints was 38.7 ± 17.7 mm(2) and 58.0 ± 24.6 mm(2), respectively. The length between the most distal and posterior point of the lateral femoral condyle and the edge of the PT footprint was 10.3 ± 2.4 mm and 14.2 ± 2.8 mm, respectively. The length between most distal and most posterior point of the lateral femoral condyle and the edge of the LCL footprint was 16.3 ± 2.3 mm and 15.5 ± 3.3 mm, respectively. Under TKA simulation, the shortest length between the PT footprint and the femoral bone resection area for the Journey II BCS and the Persona PS was 4.3 ± 2.5 mm and 3.2 ± 2.9 mm, respectively. The shortest length between the LCL footprint and the femoral bone resection area for the Journey II BCS and the Persona PS was 7.2 ± 2.3 mm and 5.6 ± 2.1 mm, respectively. The PT attachment was damaged by the bone resection of the Journey II BCS and the Persona PS TKA in 3 and 9 knees, respectively. CONCLUSION: The PT and LCL femoral attachments existed close to the femoral bone resection area of the TKA. To prevent postero-lateral instability in TKA, careful attention is needed to avoid damage to the PT and LCL during surgical procedures.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。