Inter-rater reliability, sensitivity to change and responsiveness of the orthopaedic Wolf-Motor-Function-Test as functional capacity measure before and after rehabilitation in patients with proximal humeral fractures

骨科沃尔夫运动功能测试作为近端肱骨骨折患者康复前后功能能力测量指标的评分者间信度、对变化的敏感性和反应性

阅读:4

Abstract

BACKGROUND: The incidence of proximal humeral fractures (PHF) increased by more than 30% over the last decade, which is accompanied by an increased number of operations. However, the evidence on operative vs. non-operative treatment and post-operative treatments is limited and mostly based on expert opinion. It is mandatory to objectively assess functional capacity to compare different treatments. Clinical tools should be valid, reliable and sensitive to change assessing functional capacity after PHFs. This study aimed to analyse inter-rater reliability of the videotaped Wolf-Motor-Function-Test-Orthopaedic (WMFT-O) and the association between the clinical WMFT-O and the Disability of the Arm, Shoulder and Hand (DASH) and to determine the sensitivity to change of the WMFT-O and the DASH to measure functional capacity before and after rehabilitation in PHF patients. METHODS: Fifty-six patients (61.7 ± 14.7 years) after surgical treatment of PHF were assessed using the WMFT-O at two different time points. To determine inter-rater reliability, the videotaped WMFT-O was evaluated through three blinded raters. Inter-rater agreement was determined by Fleiss' Kappa statistics. Pearson correlation coefficients were calculated to assess the association between the clinical WMFT-O and the video rating as well as the DASH. Sensitivity to change and responsiveness were analysed for the WMFT-O and the DASH in a subsample of forty patients (53.8 ± 1.4 years) who were assessed before and after a three week robotic-assisted training intervention. RESULTS: Inter-rater agreement was indicated by Fleiss' Kappa values ranging from 0.33-0.66 for functional capacity and from 0.27-0.54 for quality of movement. The correlation between the clinical WMFT-O and the video rating was higher than 0.77. The correlation between the clinical WMFT-O and the DASH was weak. Sensitivity to change was high for the WMFT-O and the DASH and responsiveness was given. In comparison to the DASH, the sensitivity to change of the WMFT-O was higher. CONCLUSION: The overall results indicate that the WMFT-O is a reliable, sensitive and responsive instrument to measure more objectively functional change over time in rehabilitation after PHF. Furthermore, it has been shown that video assessment is eligible for studies to ensure a full blinding of raters. TRIAL REGISTRATION: Clinicaltrials.gov, NCT03100201 . Registered on 28 March 2017. The trial was retrospectively registered.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。