A new clinical test for sensorimotor function of the hand - development and preliminary validation

一种用于评估手部感觉运动功能的新型临床测试——开发与初步验证

阅读:1

Abstract

BACKGROUND: Sensorimotor disturbances of the hand such as altered neuromuscular control and reduced proprioception have been reported for various musculoskeletal disorders. This can have major impact on daily activities such as dressing, cooking and manual work, especially when involving high demands on precision and therefore needs to be considered in the assessment and rehabilitation of hand disorders. There is however a lack of feasible and accurate objective methods for the assessment of movement behavior, including proprioception tests, of the hand in the clinic today. The objective of this observational cross- sectional study was to develop and conduct preliminary validation testing of a new method for clinical assessment of movement sense of the wrist using a laser pointer and an automatic scoring system of test results. METHODS: Fifty physiotherapists performed a tracking task with a hand-held laser pointer by following a zig-zag pattern as accurately as possible. The task was performed with left and right hand in both left and right directions, with three trials for each hand movement. Each trial was video recorded and analysed with a specifically tailored image processing pipeline for automatic quantification of the test. The main outcome variable was Acuity, calculated as the percent of the time the laser dot was on the target line during the trial. RESULTS: The results showed a significantly better Acuity for the dominant compared to non-dominant hand. Participants with right hand pain within the last 12 months had a significantly reduced acuity (p < 0.05), and although not significant there was also a similar trend for reduced Acuity also for participants with left hand pain. Furthermore, there was a clear negative correlation between Acuity and Speed indicating a speed-accuracy trade off commonly found in manual tasks. The repeatability of the test showed acceptable intra class correlation (ICC(2.1)) values (0.68-0.81) and standard error of measurement values ranging between 5.0-6.3 for Acuity. CONCLUSIONS: The initial results suggest that the test may be a valid and feasible test for assessment of the movement sense of the hand. Future research should include assessments on different patient groups and reliability evaluations over time and between testers.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。