Risk factors for failure of revision total hip arthroplasty using a Kerboull-type acetabular reinforcement device

使用 Kerboull 型髋臼加固装置进行翻修全髋关节置换术失败的风险因素

阅读:1

Abstract

BACKGROUND: The present study aimed to identify the risk factors associated with revision total hip arthroplasty (THA) failure using a Kerboull-type (KT) plate. METHODS: We analyzed 77 revision THAs using cemented acetabular components with a KT plate for aseptic loosening between May 2000 and March 2012. We examined the association of bone graft type, acetabular bone defects, age at the time of surgery, preoperative Japanese Orthopaedic Association (JOA) score, postoperative JOA hip score, and body mass index, with radiographic failure as the outcome. RESULTS: The 7.4-year radiographic failure survival rate was 81.6%. The survival rate was significantly different between the beta-tricalcium phosphate (β-TCP) group and the bulk allograft group (p = 0.019). The survival curves were also significantly different between the β-TCP group and bulk allograft group (p = 0.036). American Academy of Orthopaedic Surgeons type IV was significantly associated with radiographic failure (odds ratio [OR]: 15.5, 95% confidence interval [CI]: 1.4-175.4; p = 0.032). CONCLUSIONS: The midterm outcomes of revision THA indicate that type of bone graft and bone defect size may affect radiographic survival rate when using a KT plate.