Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference

利用前骨盆和正中矢状面作为参考,对260个三维半骨盆进行虚拟映射,以分析微创逆行拉力螺钉置入髋臼后柱的性别差异。

阅读:1

Abstract

BACKGROUND: Due to complex pelvic geometry, percutaneous screw placement in the posterior acetabular column can pose a major challenge even for experienced surgeons. METHODS: The present study examined the preformed bone stock of the posterior acetabular column in 260 hemipelvises. Retrograde posterior column screws were virtually implanted using iPlan CMF (BrainLAB AG, Feldkirchen, Germany); maximal implant length, maximal implant diameter and angles between the screw trajectories and the reference planes anterior pelvic plane as well as the midsagittal plane were assessed for gender-specific differences. RESULTS: The virtual analysis of the preformed bone stock column showed two constrictions of crucial clinical importance. These were located 49.6 ± 3.4 (41.0-60.2) mm (inferior margin of acetabulum) and 77.0 ± 5.6 (66.5-95.3) mm (centre of acetabulum) from the entry point of the implant in men and respectively 43.7 ± 2.3 (38.3-49.3) mm as well as 71.2 ± 3.5 (63.5-79.99) mm in women (men vs. women: p < 0.001). The entry point of the retrograde posterior column screw was located dorsal from the transition of the lower margin of the ischial tuberosity to ramus inferior pointing to the medial margin of the ischial tuberosity. In female patients, the entry point was located significantly closer to the medial margin of the ischial tuberosity. However, 7.3 mm screws can generally be used in men and women. The angle between the screw trajectory and the anterior pelvic plane in sagittal section was 14.0 ± 4.9 (2.5-28.6) °, the angle between the screw trajectory and the midsagittal plane in axial section was 31.1 ± 12.8 (1.5-77.9) ° and the angle between the screw trajectory and the midsagittal plane in coronal section was 8.4 ± 3.8 (1.5-20.0) °. For all angles, significant gender-specific differences were found (p < 0.001). CONCLUSION: Therefore, the anterior pelvic plane as well as the midsagittal plane can facilitate intraoperative orientation for retrograde posterior column screw placement considering gender-specific differences in preformed bone corridor, implant length as well as angles formed between screw trajectory and these reference planes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。