Clinical and radiological outcome following treatment of displaced lateral clavicle fractures using a locking compression plate with lateral extension: a prospective study

采用带外侧延伸的锁定加压钢板治疗移位性锁骨外侧骨折的临床和影像学结果:一项前瞻性研究

阅读:1

Abstract

BACKGROUND: Treatment of lateral fractures of the clavicle is challenging and has been controversially discussed for a long time due to high non-union rates in non-operative treatment and high complication rates in surgical treatment. Acromioclavicular joint instability due to the injury of the closely neighbored coraco-clavicular ligaments can result in a cranialization of the medial clavicle shaft. A recently developed implant showed a promising functional outcome in a small collective of patients. METHODS: In this prospective study, 20 patients with a mean age of 40.7 ± 11.3 years with a dislocated fracture of the lateral clavicle (Jäger&Breitner I-III, Neer I-III) were enrolled. All patients were surgically treated using the locking compression plate (LCP) for the superior anterior clavicle (Synthes®). Functional outcome was recorded using the Munich Shoulder Questionnaire (MSQ) allowing for qualitative self-assessment of the Shoulder Pain and Disability Index (SPADI), of the Disability of the Arm, Shoulder and Hand (DASH) score and of the Constant Score. Acromioclavicular joint stability was evaluated using the Taft-Score. RESULTS: The mean follow-up was 14.2 ± 4.0 months. The mean MSQ was 87.0 ± 7.4 points, the mean SPADI 91.1 ± 11.3 points, the mean DASH score 7.6 ± 7.3 points and the mean normative age- and sex-specific Constant Score 85.6 ± 8.0 points. The mean Taft Score resulted in 10.7 ± 1.0 points. The mean Taft Score in lateral clavicular fractures with fracture gap between the coracoclavicular ligaments in combination with a rupture of the conoid ligament (J&B II a, Neer II B; n =11) was with 10.3 ± 0.9 points significantly lower than the mean Taft Score of all other types of lateral clavicle fractures (J&B I, II b, III; n =9) which resulted in 11.3 ± 0.9 points (p<0.05). CONCLUSIONS: The Synthes® LCP superior anterior clavicle plate allows for a safe stabilization and good functional outcome with high patient satisfaction in fractures of the lateral clavicle. However, in fractures type Jäger&Breitner II a, Neer II B a significant acromioclavicular joint instability was observed and additional reconstruction of the coracoclavicular ligaments should be performed. TRIAL REGISTRATION: ClinicalTrials.gov NCT02256059. Registered 02 October 2014.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。