Heterogeneous effects of battery storage deployment strategies on decarbonization of provincial power systems in China

电池储能部署策略对中国省级电力系统脱碳的异质性影响

阅读:1

Abstract

Battery storage is critical for integrating variable renewable generation, yet how the location, scale, and timing of storage deployment affect system costs and carbon dioxide (CO(2)) emissions is uncertain. We improve a power system model, SWITCH-China, to examine three nationally uniform battery deployment strategies (Renewable-connected, Grid-connected, and Demand-side) and a heterogeneous battery deployment strategy where each province is allowed to utilize any of the three battery strategies. Here, we find that the heterogeneous strategy always provides the lowest system costs among all four strategies, where provinces with abundant renewable resources dominantly adopt Renewable-connected batteries while those with limited renewables dominantly adopt Demand-side batteries. However, which strategy achieves the lowest CO(2) emissions depends on carbon prices. The Renewable-connected strategy achieves the lowest CO(2) emissions when carbon prices are relatively low, and the heterogeneous strategy results in the lowest CO(2) emissions only at extremely high carbon prices.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。