Differences of FreeStyle Libre Flash Glucose Monitoring System and Finger Pricks on Clinical Characteristics and Glucose Monitoring Satisfactions in Type 1 Diabetes Using Insulin Pump

FreeStyle Libre瞬感血糖监测系统与指尖采血在1型糖尿病胰岛素泵使用者临床特征和血糖监测满意度方面的差异

阅读:1

Abstract

BACKGROUND: To evaluate the different experience of freestyle libre and finger pricks on clinical characteristics and glucose monitoring satisfaction (GMS) in patients with type 1 diabetes (T1D) using insulin pump (IP). METHODS: A prospective study was carried out on 47 (aged 17-21 years) T1D, who used conventional finger-pricking method for self-testing the glucose. The experiments were conducted between March 2018 and September 2018. For carrying out the study, the flash glucose monitoring (FGM) sensors were placed on each participant, at the baseline visit, by a trained diabetes educator. Furthermore, to determine the total number of scans conducted during the study period, the respective ambulatory glucose profiles were generated by computing the data collected from the sensors. In addition, a trained interviewer handed over the GMS questionnaire to each patient, at the baseline and at 12 weeks of the study. RESULTS: In comparison to the baseline (finger pricks), various parameters such as: HbA1c (P = .042), hypoglycemia (P = .001), mean capillary glucose (P = .004), total daily insulin dose (P = .0001), percentage of bolus insulin (P = .0001), daily bolus frequency (P = .0001), and daily carbohydrates intake (P = .0001) showed a significant improvement at 12 weeks. Similarly, substantial augmentation was noticed, in the sub domains of GMS, that is, openness (P = .0001), emotional burden (P = .0001), behavioral burden (P = .0001), and trust (P = .0001) at 12 weeks as compared to baseline. Overall, total GMS score at baseline was 1.72 ± 0.37, which increased up to 3.41 ± 0.49 (P = .0001) in the time period of 12 weeks. The HbA1c (r(2) = 0.45), hypoglycemia (r(2) = 0.58), and the mean number of FGM scans, exhibited a negative correlation, while GMS (r(2) = 0.52) and the mean number of FGM scans, exhibited a positive correlation. CONCLUSION: The frequency of hypoglycemia, HbA1c level, capillary glucose, daily carbohydrates intake decreased, while the total daily insulin dose, daily bolus insulin and total GMS score increased with the use of FGM scanning for 12 weeks.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。