Use of noninvasive gas exchange to track pulmonary vascular responses to exercise in heart failure

利用无创气体交换技术追踪心力衰竭患者运动时肺血管的反应

阅读:1

Abstract

We determined whether a non-invasive gas exchange based estimate of pulmonary vascular (PV) capacitance [PVCAP = stroke volume (SV) × pulmonary arterial pressure (Ppa)] (GXCAP) tracked the PV response to exercise in heart-failure (HF) patients. Pulmonary wedge pressure (Ppw), Ppa, PV resistance (PVR), and gas exchange were measured simultaneously during cycle exercise in 42 HF patients undergoing right-heart catheterization. During exercise, PETCO2 and VE/VCO2 were related to each other (r = -0.93, P < 0.01) and similarly related to mean Ppa (mPpa) (r = -0.39 and 0.36; P < 0.05); PETCO2 was subsequently used as a metric of mPpa. Oxygen pulse (O2 pulse) tracked the SV response to exercise (r = 0.91, P < 0.01). Thus, GXCAP was calculated as O2 pulse × PETCO2. During exercise, invasively determined PVCAP and non-invasive GXCAP were related (r = 0.86, P < 0.01), and GXCAP correlated with mPpa and PVR (r = -0.46 and -0.54; P < 0.01). In conclusion, noninvasive gas exchange measures may represent a simple way to track the PV response to exercise in HF.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。