A Case of TAV-in-SAV in a Patient with Structural Valve Deterioration after Surgical Aortic Valve Replacement with the INSPIRIS RESILIA Valve

一例主动脉瓣置换术后出现结构性瓣膜退化的患者,在接受 INSPIRIS RESILIA 瓣膜置换术后出现主动脉瓣中瓣 (TAV-in-SAV) 的病例报告

阅读:1

Abstract

The INSPIRIS RESILIA valve is designed to dilate its valve annulus in transcatheter aortic valve-in-surgical aortic valve (TAV-in-SAV), a catheter therapy for biological valve deterioration. RESILIA tissue has improved anti-calcification properties. An 83-year-old man on hemodialysis undergoing surgical aortic valve replacement (SAVR) with a 25-mm INSPIRIS for severe aortic stenosis 22 months ago presented with general malaise. Transthoracic echocardiography revealed severe bioprosthetic stenosis (peak velocity: 3.5 m/s, mean pressure gradient: 32 mmHg, and effective orifice area: 0.45 cm(2)) and severely reduced left ventricular function (ejection fraction: 17%). Because redo-SAVR was extremely risky (society of thoracic surgeons [STS] risk score: 31%), the patient underwent transfemoral-TAV-in-SAV using a 26-mm SAPIEN 3️. Pre- and postoperative computed tomography showed that the internal diameter of the INSPIRIS had expanded from 22.2 mm to 24.2 mm. This case demonstrated the dilatable design of INSPIRIS but not the durability of RESILIA tissue.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。