Increase Carotid Flow by Double Sheath Connection Technique to Reduce Cerebral Ischemia for Transcatheter Aortic Valve Implantation through Transcarotid Approach

采用双鞘连接技术增加颈动脉血流,以减少经颈动脉途径行经导管主动脉瓣置换术时的脑缺血。

阅读:1

Abstract

PURPOSE: Transcarotid transcatheter aortic valve implantation (TAVI) is one alternative approach if unfavorable femoral access. However, this approach may cause cerebral vascular accidents (CVAs) by temporarily occluding common carotid artery (CCA). The purpose of this study is to develop a new method reducing cerebral ischemia during transcarotid TAVI. METHODS: We inserted an 8- and 18-Fr. sheath in CCA with tip toward brain and aortic arch, respectively, and connected their side arms to create a bypass flow. Medtronic CoreValve was then delivered and deployed in position after pre-TAVI balloon dilatation. RESULTS: Three patients received this implantation. There were no CVAs or transient ischemic attacks (TIAs) after the procedure and all patients had been followed up uneventfully for 1 year. CONCLUSION: Our technique is feasible and potentially reduces stroke in transcarotid TAVI.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。