Safety of ventricular tachycardia ablation in clinical practice: findings from 9699 hospital discharge records

室性心动过速消融术在临床实践中的安全性:来自 9699 份医院出院记录的发现

阅读:1

Abstract

BACKGROUND: Outcomes of ventricular tachycardia (VT) ablation have been described in clinical trials and single-center studies. We assessed the safety of VT ablation in clinical practice. METHODS AND RESULTS: Using administrative hospitalization data between 1994 and 2011, we identified hospitalizations with primary diagnosis of VT (International Classification of Diseases-9 Clinical Modification code: 427.1) and cardiac ablation (International Classification of Diseases-9 Clinical Modification code: 37.34). We quantified in-hospital adverse events (AEs), including death, stroke, intracerebral hemorrhage, pericardial complications, hematoma or hemorrhage, blood transfusion, or cardiogenic shock. Secondary outcomes included major AEs (stroke, tamponade, or death) and death. Multivariable mixed effects models identified patient and hospital characteristics associated with AEs. Of 9699 hospitalizations with VT ablations (age, 56.5 ± 17.6; 60.1% men), AEs were reported in 825 (8.5%), major AEs in 295 (3.0%), and death in 110 (1.1%). Heart failure had the strongest association with death (odds ratio, 5.52; 95% confidence interval, 2.97-10.3) and major AE (odds ratio, 2.99; 95% confidence interval, 2.15-4.16). Anemia (odds ratio, 4.84; 95% confidence interval, 3.79-6.19) and unscheduled admission (odds ratio, 1.64; 95% confidence interval, 1.37-1.97) were associated with AEs. During the study period, incidence of AEs increased from 9.2% to 12.8% as did the burden of AE risk factors (0.034 patient/y; P < 0.001). Hospital volume > 25 cases/y was associated with fewer AEs compared with lower volume centers (6.4% versus 8.8%; P = 0.008). CONCLUSIONS: VT ablation-associated AE rates in clinical practice are similar to those reported in the literature. Over time rates have increased as have the number of AE risk factors per patient. Ablations done electively and at hospitals with higher procedural volume are associated with lower incidence of AEs.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。