Staging achilles tendinopathy using ultrasound imaging: the development and investigation of a new ultrasound imaging criteria based on the continuum model of tendon pathology

利用超声成像对跟腱病变进行分期:基于肌腱病理连续体模型的新型超声成像标准的建立与研究

阅读:1

Abstract

AIM: To develop a standardised ultrasound imaging (USI)-based criteria for the diagnosis of tendinopathy that aligns with the continuum model of tendon pathology. Secondary aims were to assess both the intra-rater and inter-rater reliability of the criteria. METHODS: A criteria was developed following a face validity assessment and a total of 31 Achilles tendon ultrasound images were analysed. Intra-rater and inter-rater reliability were assessed for overall tendinopathy stage (normal, reactive/early dysrepair or late dysrepair/degenerative) as well as for individual parameters (thickness, echogenicity and vascularity). Quadratic weighted kappa (k(w)) was used to report on reliability. RESULTS: Intra-rater reliability was 'substantial' for overall tendinopathy staging (k(w) rater A; 0.77, 95% CI 0.59 to 0.94, rater B; 0.70, 95% CI 0.52 to 0.89) and ranged from 'substantial' to 'almost perfect' for thickness (k(w) rater A; 0.75, 95% CI 0.59 to 0.90, rater B; 0.84, 95% CI 0.71 to 0.98), echogenicity (k(w) rater A; 0.78, 95% CI 0.62 to 0.95, rater B; 0.73, 95% CI 0.58 to 0.89) and vascularity (k(w) rater A; 0.86, 95% CI 0.74 to 0.98, rater B; 0.89, 95% CI 0.79 to 0.99). Inter-rater reliability ranged from 'substantial' to 'almost perfect' for overall tendinopathy staging (k(w) round 1; 0.75, 95% CI 0.58 to 0.91, round 2; 0.81, 95% CI 0.63 to 0.99), thickness (k(w) round 1; 0.65, 95% CI 0.48 to 0.83, round 2; 0.77, 95% CI 0.60 to 0.93), echogenicity (k(w) round 1; 0.70, 95% CI 0.54 to 0.85, round 2; 0.76, 95% CI 0.58 to 0.94) and vascularity (k(w) round 1; 0.89, 95% CI 0.79 to 0.99, round 2; 0.86, 95% CI 0.74 to 0.98). Inter-rater reliability increased from 'substantial' in round 1 (k(w) 0.75, 95% CI 0.58 to 0.91) to 'almost perfect' in round 2 (0.81, 95% CI 0.63 to 0.99). CONCLUSION: Intra-rater and inter-rater reliability were 'substantial' to 'almost perfect' when utilising an USI-based criteria to diagnose Achilles tendinopathy. This is the first study to use the continuum model of tendon pathology to develop an USI-based criteria to diagnose tendinopathy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。