CPR performance in the presence of audiovisual feedback or football shoulder pads

在视听反馈或橄榄球肩垫存在的情况下进行心肺复苏术

阅读:1

Abstract

OBJECTIVE: The initiation of cardiopulmonary resuscitation (CPR) can be complicated by the use of protective equipment in contact sports, and the rate of success in resuscitating the patient depends on the time from incident to start of CPR. The aim of our study was to see if (1) previous training, (2) the presence of audiovisual feedback and (3) the presence of football shoulder pads (FSP) affected the quality of chest compressions. METHODS: Six basic life support certified athletic training students (BLS-ATS), six basic life support certified emergency medical service personnel (BLS-EMS) and six advanced cardiac life support certified emergency medical service personnel (ACLS-EMS) participated in a crossover manikin study. A quasi-experimental repeated measures design was used to measure the chest compression depth (cm), rate (cpm), depth accuracy (%) and rate accuracy (%) on four different conditions by using feedback and/or FSP. Real CPR Help manufactured by ZOLL (Chelmsford, Massachusetts, USA) was used for the audiovisual feedback. Three participants from each group performed 2 min of chest compressions at baseline first, followed by compressions with FSP, with feedback and with both FSP and feedback (FSP+feedback). The other three participants from each group performed compressions at baseline first, followed by compressions with FSP+feedback, feedback and FSP. RESULTS: CPR performance did not differ between the groups at baseline (median (IQR), BLS-ATS: 5.0 (4.4-6.1) cm, 114(96-131) cpm; BLS-EMS: 5.4 (4.1-6.4) cm, 112(99-131) cpm; ACLS-EMS: 6.4 (5.7-6.7) cm, 138(113-140) cpm; depth p=0.10, rate p=0.37). A statistically significant difference in the percentage of depth accuracy was found with feedback (median (IQR), 13.8 (0.9-49.2)% vs 69.6 (32.3-85.8)%; p=0.0002). The rate accuracy was changed from 17.1 (0-80.7)% without feedback to 59.2 (17.3-74.3)% with feedback (p=0.50). The use of feedback was effective for depth accuracy, especially in the BLS-ATS group, regardless of the presence of FSP (median (IQR), 22.0 (7.3-36.2)% vs 71.3 (35.4-86.5)%; p=0.0002). CONCLUSIONS: The use of audiovisual feedback positively affects the quality of the depth of CPR. Both feedback and FSP do not alter the rate measurements. Medically trained personnel are able to deliver the desired depth regardless of the presence of FSP even though shallower chest compressions depth can be seen in CPR with FSP. A feedback device must be introduced into the athletic training settings.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。