Validity of Estimating the Maximal Oxygen Consumption by Consumer Wearables: A Systematic Review with Meta-analysis and Expert Statement of the INTERLIVE Network

利用消费级可穿戴设备估算最大摄氧量的有效性:INTERLIVE网络的系统评价、荟萃分析和专家声明

阅读:1

Abstract

BACKGROUND: Technological advances have recently made possible the estimation of maximal oxygen consumption (VO(2max)) by consumer wearables. However, the validity of such estimations has not been systematically summarized using meta-analytic methods and there are no standards guiding the validation protocols. OBJECTIVE: The aim was to (1) quantitatively summarize previous studies investigating the validity of the VO(2max) estimated by consumer wearables and (2) provide best-practice recommendations for future validation studies. METHODS: First, we conducted a systematic review and meta-analysis of studies validating the estimation of VO(2max) by wearables. Second, based on the state of knowledge (derived from the systematic review) combined with the expert discussion between the members of the Towards Intelligent Health and Well-Being Network of Physical Activity Assessment (INTERLIVE) consortium, we provided a set of best-practice recommendations for validation protocols. RESULTS: Fourteen validation studies were included in the systematic review and meta-analysis. Meta-analysis results revealed that wearables using resting condition information in their algorithms significantly overestimated VO(2max) (bias 2.17 ml·kg(-1)·min(-1); limits of agreement - 13.07 to 17.41 ml·kg(-1)·min(-1)), while devices using exercise-based information in their algorithms showed a lower systematic and random error (bias - 0.09 ml·kg(-1)·min(-1); limits of agreement - 9.92 to 9.74 ml·kg(-1)·min(-1)). The INTERLIVE consortium proposed six key domains to be considered for validating wearable devices estimating VO(2max), concerning the following: the target population, reference standard, index measure, testing conditions, data processing, and statistical analysis. CONCLUSIONS: Our meta-analysis suggests that the estimations of VO(2max) by wearables that use exercise-based algorithms provide higher accuracy than those based on resting conditions. The exercise-based estimation seems to be optimal for measuring VO(2max) at the population level, yet the estimation error at the individual level is large, and, therefore, for sport/clinical purposes these methods still need improvement. The INTERLIVE network hereby provides best-practice recommendations to be used in future protocols to move towards a more accurate, transparent and comparable validation of VO(2max) derived from wearables. PROSPERO ID: CRD42021246192.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。