Balloon-assisted ExoSeal closure for inadvertent subclavian artery cannulation following central venous catheterization: A case report

中心静脉置管术后意外锁骨下动脉插管行球囊辅助下ExoSeal封堵术:病例报告

阅读:2

Abstract

Accidental arterial puncture is a rare but significant complication associated with central venous catheterization. This report describes a case of inadvertent subclavian artery catheterization that was successfully managed with the ExoSeal vascular closure device. A female patient in her early 30s was hospitalized for severe acute pancreatitis that necessitated cannulation of the right subclavian vein. Postprocedure, infusion difficulties suggested a need for arterial catheterization, which was confirmed by imaging. The intervention resulted in prompt hemostasis and prevented further vascular injury, resulting in complication-free recovery. This case highlights the importance of rapid identification and treatment of arterial injury during central venous catheterization, and also demonstrates the effectiveness of ExoSeal in the management of vascular complications, especially in high-risk conditions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。