Microwave attenuation of two-way radio according to building material and smoke in disaster environments

灾害环境中建筑材料和烟雾对双向无线电微波衰减的影响

阅读:1

Abstract

Disaster environments, such as fires, distort of two-way radio communication within buildings. This article presents an experimental study on microwave attenuation based on the smoke and wall type in a disaster environment using a two-way radio with digital mobile radio communication, widely used by firefighting crews in Korea. Furthermore, we compared the microwave attenuation of the two-way radio depending on the building materials and smoke. We then present the experimental result of the microwave characteristic corresponding to the four types of walls in a specially designed anechoic chamber (3 m × 1 m × 1 m) to analyze the microwave attenuation by the building materials, with results indicating up to 82% in 200 mm thick concrete. Moreover, we evaluated the propagation attenuation based on the four types of smoke with the same density in a container space (5.8 m × 2.8 m × 2.2 m). The results showed that the microwaves were not transmitted and significantly decreased based on the building materials at 400 MHz, which is the main cause of attenuation. It shows a property of up to 36% reduction in urethane. Although the attenuation of microwaves is not significantly large according to the fuels in smoke, fuels such as urethane, plastic, and rubber have relatively small attenuation of microwaves compared to wood, and the received power corresponding to urethane in smoke decreased the most.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。