Application of TINAVI orthopedic robot-assisted proximal interlocking screw placement for femoral retrograde intramedullary nails: a retrospective clinical study

TINAVI骨科机器人辅助近端锁定螺钉置入术在股骨逆行髓内钉中的应用:一项回顾性临床研究

阅读:1

Abstract

Retrograde intramedullary nailing is a common treatment for middle and lower femoral fractures where proximal locking is the main challenge. This study explored the application and experience of robot-assisted retrograde intramedullary nail proximal precision locking. Data from 74 patients with middle and lower femoral fractures treated with retrograde intramedullary nails between January 2021 and June 2023 were retrospectively analyzed. According to the different proximal locking methods, the data were divided into a robotic group (34 cases) and a free-hand group (40 cases). General, perioperative, and follow-up data of the two groups were collected, and their differences were compared based on specified parameters. The results are as follows: the mean follow-up time was (16.10 ± 2.38) months, the number of screw placements in the robotic group (1.03 ± 0.17) was less than that in the manual group (1.63 ± 1.15, P = 0.004), and the number of fluoroscopies (1.06 ± 0.34) was significantly less than that in the manual group (6.35 ± 2.46, P < 0.001). Additionally, the total length of the proximal incision (2.16 ± 0.24) was shorter than that in the manual group (3.58 ± 0.38, P < 0.001), and the success rate of one-time screw placement (97.1%, 33/34) was significantly higher than that in the manual group (67.5%, 27/40; P = 0.001). There were no significant differences in the other indices of the two groups (P > 0.05). For the treatment of the middle and lower femoral fractures using a femoral retrograde intramedullary nail, the robotic navigation system is more efficient than traditional manual nail placement under fluoroscopy because it can shorten the number of proximal locking nail placements, the number of fluoroscopies, and the total length of the proximal incision. Additionally, it can reduce the exposure to external radiation and increase the success rate of one-time nail placement. Thus, this study presents a novel approach for the placement of proximal interlocking screws in femoral retrograde intramedullary nails, making it worthy of clinical application.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。