BACKGROUND: Research into artificial intelligence (AI)-based fracture detection in children is scarce and has disregarded the detection of indirect fracture signs and dislocations. OBJECTIVE: To assess the diagnostic accuracy of an existing AI-tool for the detection of fractures, indirect fracture signs, and dislocations. MATERIALS AND METHODS: An AI software, BoneView (Gleamer, Paris, France), was assessed for diagnostic accuracy of fracture detection using paediatric radiology consensus diagnoses as reference. Radiographs from a single emergency department were enrolled retrospectively going back from December 2021, limited to 1,000 radiographs per body part. Enrolment criteria were as follows: suspected fractures of the forearm, lower leg, or elbow; age 0-18 years; and radiographs in at least two projections. RESULTS: Lower leg radiographs showed 607 fractures. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were high (87.5%, 87.5%, 98.3%, 98.3%, respectively). Detection rate was low for toddler's fractures, trampoline fractures, and proximal tibial Salter-Harris-II fractures. Forearm radiographs showed 1,137 fractures. Sensitivity, specificity, PPV, and NPV were high (92.9%, 98.1%, 98.4%, 91.7%, respectively). Radial and ulnar bowing fractures were not reliably detected (one out of 11 radial bowing fractures and zero out of seven ulnar bowing fractures were correctly detected). Detection rate was low for styloid process avulsions, proximal radial buckle, and complete olecranon fractures. Elbow radiographs showed 517 fractures. Sensitivity and NPV were moderate (80.5%, 84.7%, respectively). Specificity and PPV were high (94.9%, 93.3%, respectively). For joint effusion, sensitivity, specificity, PPV, and NPV were moderate (85.1%, 85.7%, 89.5%, 80%, respectively). For elbow dislocations, sensitivity and PPV were low (65.8%, 50%, respectively). Specificity and NPV were high (97.7%, 98.8%, respectively). CONCLUSIONS: The diagnostic performance of BoneView is promising for forearm and lower leg fractures. However, improvement is mandatory before clinicians can rely solely on AI-based paediatric fracture detection using this software.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。