Bicuspid aortic valve repair adapted to aortic phenotype

适应主动脉表型的二叶式主动脉瓣修复

阅读:1

Abstract

The bicuspid aortic valve (BAV) is the most common congenital cardiovascular anomaly and may present with differing phenotypes including almost constant annular dilation. We have developed a standardized approach to BAV repair with a systematic adjunct of aortic annuloplasty according to the three phenotypes of the proximal aorta, which include a dilated aortic root, dilated ascending aorta and normal root and ascending aorta. In our cohort of 191 patients, freedom from AV-related re-intervention was 98% for remodeling with annuloplasty (n=100) and 100% for tubular aortic replacement with annuloplasty (n=31) at 8 years. In an isolated aortic insufficiency (AI) group, freedom from AV-related re-intervention varied from 72.4% with a single subvalvular annuloplasty ring (n=31) compared to 100% at 6 years when a double sub- and supra-valvular (STJ) annuloplasty ring was performed (n=29). Restoration of the annulus: sinotubular junction (STJ) ratio is a key factor to ensure longevity of the bicuspid valve repair and freedom from re-intervention.