Comparison of experimental data obtained using the reference and the single-serpentine proton exchange membrane single fuel cell testing hardware

对使用参考硬件和单蛇形质子交换膜单燃料电池测试硬件获得的实验数据进行比较

阅读:1

Abstract

The paper presents testing data of single Polymer Electrolyte Membrane (PEM) fuel cell for comparing the characteristics of two different testing hardware, namely the recently developed single cell reference testing hardware and the commonly used by the research community single-serpentine testing hardware. Data are presented in form of polarisation curves, temperature, pressure and voltage distributions, as well as electrochemical impedance spectroscopy measurements for a range of current densities. The electrochemical impedance spectroscopy data are also validated using the Kramers-Kronig transformation and presented as Nyquist and Bode plots. The raw data of all mentioned results are also provided in online repository. The presented experimental data are discussed and evaluated in Assessment of the electrochemical characteristic of a Polymer Electrolyte Membrane in a "reference" single fuel cell testing hardware[1].

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。