Adaptations of a competitive enzyme-linked immunosorbent assays for the detection of antibodies to influenza a virus in horse sera for use in wild aquatic birds

改进竞争性酶联免疫吸附试验以检测野生水鸟马血清中的甲型流感病毒抗体

阅读:7
作者:M A Hoque, L F Skerratt, S Garland, G W Burgess, P Selleck

Abstract

We applied a competitive enzyme-linked immunosorbent assay for the detection of antibodies for influenza A in equine sera to their detection in sera from wild aquatic birds. Suboptimal results were obtained for the optical density (OD) of the monoclonal antibody (MAb) control and reproducibility between duplicate analyses in the initial assessment. It was therefore necessary to modify the assay to deliver increased reliability and reproducibility while maintaining adequate sensitivity. We optimized reagent concentrations to obtain optimal OD values (close to 2) for the monoclonal antibody control and used 2, 2'-Azino-bis: 3-Benzthiazoline-6-Sulphonic Acid as an alternative chromogen to potentially reduce variability in duplicate analyses. The original assay was compared with the optimized versions, with and without post coating, for the detection of avian influenza viral antibodies in 240 sera obtained from wild plumed whistling ducks. A separate analytical sensitivity study on diluted positive field sera of plumed whistling ducks and a test of antigen stability after post coating were also performed. Some quantitative differences were detected between the original and modified assays. The original assay recorded higher percentage inhibition results which were potentially indicative of increased sensitivity. However, when reagent concentrations were increased in the original assay to the same levels as used in the modified versions, there were no quantitative differences for practical purposes. The original assay produced a median (OD) value of 0.81 for the (MAb) controls that is at the limit of acceptability. By contrast, the modified assays always produced acceptable optical density values for MAb controls. Our overall results indicated the modified assays were potentially more reliable (OD values close to 2), and of adequate sensitivity compared to the original assay in the detection of avian influenza viral antibodies in wild bird sera. Although further optimization of antigen and MAb concentrations should also be considered to increase the sensitivity of a modified assay, while maintaining acceptable optical density values for the MAb control. Post coating had a minimal quantitative effect on the results and stabilized the plates for 214 days. We therefore recommend the incorporation of post coating.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。