The urine foaming test in COVID-19 as a useful tool in diagnosis, prognosis and follow-up: Preliminary results

尿液泡沫试验在新冠肺炎诊断、预后和随访中的应用:初步结果

阅读:1

Abstract

OBJECTIVE: We aimed to develop a simple, rapid urine test based on the level of foaming that occurs in the urine sample due to the excretion of peptide structures containing amino acids specific to the antigenic structure of COVID-19. In this study, we present the preliminary results of the first clinical study with a newly developed urine foaming test (UFT). METHODS: This study was conducted in a tertiary hospital in Istanbul. After obtaining the approval of the ethics committee, urine samples were taken from three groups of patients whose informed consent was obtained. The groups were created according to the COVID-19 Diagnostic Guide of Ministry of Health: A: outpatients with suspected COVID-19, B: inpatients for follow-up and treatment, C: patients treated in intensive care unit (ICU). Also, 30 healthy volunteers were included as the control group D. Urine samples taken from all groups were delivered to the laboratory. 2.5 ml urine sample was added to the test tube and shaken for 15 seconds and the level of foam formed was visually evaluated according to the color scale. Other data of the patients were obtained from the hospital information management system and the physician caring for the patient. The clinical status, PCR test results, computed tomography (CT), if any, laboratory tests, and UFT results were compared and the level of statistical significance was expressed as p≤0.05 in the 95% confidence intervals (CI). Performance characteristics, such as sensitivity, specificity, positive and negative predictive value of the UFT, were statistically calculated according to the RT-PCR result and/or CT. RESULTS: A statistically significant difference was observed between UFT distributions of the control, outpatient, inpatient and ICU patients (p=0.0001). The results of UFT orange and red in inpatients and ICU patients were statistically significantly higher than in the control and outpatient groups. The diagnostic accuracy of UFT was detected in all group, the pooled sensitivity was 92% (95% CI: 87-95%) and specificity was 89% (95% CI: 80-98%). CONCLUSION: Our preliminary results suggest that the UFT is useful, particularly in predicting the clinical severity of COVID-19. The UFT could be recommended as a point of care test, rapid and non-invasive method in the diagnosis and follow-up of COVID-19.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。