Twenty-Four Hour Fasting (Basal Rate) Tests to Achieve Custom-Tailored, Hour-by-Hour Basal Insulin Infusion Rates in Patients With Type 1 Diabetes Using Insulin Pumps (CSII)

24 小时空腹(基础率)测试,用于为使用胰岛素泵(CSII)的 1 型糖尿病患者实现个性化、逐小时的基础胰岛素输注率

阅读:1

Abstract

BACKGROUND: Twenty-four hour fasting periods are being used to scrutinize basal insulin infusion rates for pump-treated patients with type 1 diabetes. METHODS: Data from 339 consecutive in-patients with adult type 1 diabetes on insulin pump therapy undergoing a 24-hour fast as a basal rate test were retrospectively analyzed. Hourly programmed basal insulin infusion rates and plasma glucose concentrations within, below, or above arbitrarily defined target ranges were assessed for periods of the day of special interest (eg, 01:00-07:00 am, "dawn" period, 04:00-07:00 pm, and "dusk" period). Statistics: χ(2)-tests, paired t-tests were used. RESULTS: Basal rates (mean: 0.90 ± 0.02 IU/h) showed circadian variations with peaks corresponding to "dawn" (1.07 ± 0.02 IU/h from 01:00 to 07:00 am) and, less prominently, "dusk" (0.95 ± 0.02 IU/h from 03:00 to 07:00 pm). Individual mean plasma glucose concentrations averaged 6.6 ± 0.1 mmol/L, with 53.1% in the predefined "strict" (4.4-7.2 mmol/L) target range. Interestingly, during the "dawn" period, plasma glucose was significantly higher (by 0.5 ± 0.1 mmol/L [95% confidence interval: 0.3-0.8 mmol/L; P < .0001]) and the odds ratio for hypoglycemia was significantly lower compared to the reference period. INTERPRETATION: Twenty-four hour fasting periods as basal rate tests frequently unravel periods with inappropriate basal insulin infusion rates potentially responsible for fasting hyper- or hypoglycemia. Notably, the higher basal insulin infusion rate found during the "dawn" period seems to be justified and may need to be accentuated.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。