Three-dimensionally printed navigational template: a promising guiding approach for lung biopsy

三维打印导航模板:一种很有前景的肺活检引导方法

阅读:1

Abstract

BACKGROUND: Percutaneous transthoracic lung biopsy is customarily conducted under computed tomography (CT) guidance, which primarily depends on the conductors' experience and inevitably contributes to long procedural duration and radiation exposure. Novel technique facilitating lung biopsy is currently demanded. METHODS: Based on the reconstructed anatomical information of CT scans, a three-dimensionally printed navigational template was customized to guide fine-needle aspiration (FNA). The needle insertion site and angle could be indicated by the template after proper placement according to the reference landmarks. From June 2020 to August 2020, patients with peripheral indeterminate lung lesions ≥30 mm in diameter were enrolled in a pilot trial. Cases were considered successful when the virtual line indicated by the template in the first CT scan was pointing at the target, and the rate of success was recorded. The insertion deviation, procedural duration, radiation exposure, biopsy-related complications, and diagnostic yield were documented as well. RESULTS: A total of 20 patients consented to participate, and 2 withdrew. The remaining 18 participants consisting of 11 men and 7 women with a median age of 63 [inter-quartile range (IQR), 50-68] years and a median body mass index (BMI) of 23.5 (IQR, 20.8-25.8) kg/m(2) received template-guided FNA. The median nodule size of the patients was 41.2 (IQR, 36.2-51.9) mm and 17 lesions were successfully targeted (success rate, 94.4%). One lesion was not reached through the designed trajectory due to an unpredictable alteration of the lesion's location resulting from pleural effusion. The median deviation between the actual position of the needle tip and the designed route was 9.4 (IQR, 6.8-11.7) mm. The median procedural duration was 10.7 (IQR, 9.7-11.8) min, and the median radiation exposure was 220.9 (IQR, 198.6-249.5) mGy×cm. No major biopsy-related complication was encountered. Definitive diagnosis of malignancy was reached in 13 of the 17 (76.5%) participants. CONCLUSIONS: The feasibility and safety of navigational template-guided FNA were preliminarily validated in lung biopsy cohort. Nonetheless, patients with pleural effusion were not recommended to undergo FNA guided by such technique. TRIAL REGISTRATION: This study was registered with ClinicalTrials.gov (identifier: NCT03325907).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。