Use of titanium mesh for middle cranial fossa skull base reconstruction

钛网在颅中窝颅底重建中的应用

阅读:1

Abstract

Objectives Temporal bone encephaloceles are usually encountered in the setting of a congenital defect of the tegmen or as an acquired defect after mastoid surgery. A variety of methods have been described in the literature for rigid reconstruction of tegmen defects. We introduce a new method of repair using orbital floor titanium mesh reconstruction plates to reconstruct the floor of the middle cranial fossa, and evaluate the outcomes, complications, and recurrence rates of temporal bone encephaloceles with this technique. Design Retrospective chart review of consecutively treated patients. Setting Tertiary care academic center. Participants Eight patients with middle cranial fossa skull base defects from January 2007 to February 2011. Main Outcome Measures Outcome measures included resolution of cerebrospinal fluid leak (CSF) and development of postoperative infection. Results One of nine patients had a postoperative CSF (cerebrospinal fluid) leak. There were no long-term complications of CSF leak or infection. Conclusions Titanium mesh is a safe and effective substitute for bone grafts in reconstruction of the middle cranial fossa skull base when rigid reconstruction is required.